Mobil dizel generatori va statsionar dizel generatorining asosiy modellari
MA'LUMOT UCHUN
|
Model |
Quvvat (KVt/KVA) |
Dizel dvigatel modeli |
Silindr raqami |
O'lchamlari (U x G x Y) MM |
N.W. (KGS) |
|
|
Boshlang'ich |
Kuting |
|||||
|
SN2200B |
2750/2200 |
3000/2400 |
12M55D2450E310 |
12V |
6100*2350*2800 |
17500 |
|
SN1800B |
2250/1800 |
2500/2000 |
12M55D2210E310 |
12V |
6100*2350*2800 |
17200 |
|
SN1650B |
2060/1650 |
2250/1800 |
12M55D2020E310 |
12V |
6100*2350*2800 |
16900 |
|
SN1600B |
2000/1600 |
2200/1760 |
12M55D1870E310 |
12V |
6100*2350*2800 |
16600 |
|
SN1500B |
1875/1500 |
2060/1650 |
16M33D1800E310 |
16V |
5200*2250*2700 |
12300 |
|
SN1400B |
1750/1400 |
1925/1540 |
16M33D1680E310 |
16V |
5200*2250*2700 |
11900 |
|
SN1360B |
1700/1360 |
1875/1500 |
16M33D1580E310 |
16V |
5200*2250*2700 |
11600 |
|
SN1280B |
1600/1280 |
1750/1400 |
16M33D1530E310 |
16V |
5200*2250*2700 |
11100 |
|
SN1200B |
1500/1200 |
1650/1320 |
16M33D1400E310 |
16V |
5200*2250*2700 |
10800 |
|
SN1100B |
1375/1100 |
1500/1200 |
12M33D1320E200 |
12V |
4800*2200*2500 |
7800 |
|
SN1000B |
1250/1000 |
1375/1100 |
12M33D1210E200 |
12V |
4800*2200*2500 |
7500 |
|
SN900B |
1125/900 |
1250/1000 |
12M33D1108E200 |
12V |
4650*2200*2500 |
6900 |
|
SN850B |
1063/850 |
1163/930 |
12M26D968E200 |
12V |
4350*2000*2300 |
6600 |
|
SN780B |
975/780 |
1075/860 |
12M26D902E200 |
12V |
4350*2000*2300 |
6500 |
|
SN770B |
875/700 |
936/770 |
12M26D792E200 |
12V |
4350*2000*2200 |
6000 |
|
SN660B |
825/660 |
900/720 |
12M26D748E200 |
12V |
4350*2000*2200 |
5800 |
|
SN600B |
750/600 |
825/660 |
6M33D670E200 |
6L |
3800*1600*2100 |
4650 |
|
SN550B |
687/550 |
750/600 |
6M33D33E200 |
6L |
3800*1600*2100 |
4500 |
|
SN500B |
625/500 |
687/550 |
6M33D572E200 |
6L |
3700*1600*2100 |
4400 |
|
SN460B |
575/460 |
625/500 |
6M33D572E200 |
6L |
3700*1600*2100 |
4300 |
|
SN420B |
525/420 |
575/460 |
6M26D484E200 |
6L |
3700*1500*2000 |
4000 |
|
SN380B |
475/380 |
525/420 |
6M26D447E200 |
6L |
3700*1360*2000 |
3900 |
|
SN360W |
450/360 |
500/400 |
WP13D405E200 |
6L |
3050*1250*2100 |
3500 |
|
SN330W |
412/330 |
450/360 |
WP13D385E200 |
6L |
3050*1250*2100 |
3200 |
|
SN300W |
375/300 |
412/330 |
WP13D385E200 |
6L |
3050*1250*2100 |
2820 |
|
SN280W |
350/280 |
387/310 |
WP12D317E200 |
6L |
3000*1200*2000 |
2550 |
|
SN250W |
312/250 |
350/280 |
WP10D320E200 |
6L |
3000*1200*2000 |
2380 |
|
SN200W |
250/200 |
275/220 |
WP10D238E200 |
6L |
2900*1200*1800 |
1980 |
|
SN128W |
160/128 |
175/140 |
WP6D152E200 |
6L |
2400*950*1500 |
1400 |
|
SN150W |
187/150 |
206/165 |
WP6D167E200 |
6L |
2400*950*1500 |
1480 |
|
SN90W |
112/90 |
125/100 |
WP4.1D100E200 |
4L |
2100*950*1400 |
1150 |
|
SN60W |
69/55 |
75/60 |
WP4.1D66E200 |
4L |
1950*950*1400 |
890 |
|
SN44W |
50/40 |
55/44 |
WP2.3D48E200 |
4L |
1750*760*1350 |
720 |
Kafolat
Harakatlanuvchi dizel generatori texnik xizmat ko'rsatish vaqti qoidalariga qat'iy rioya qilishi kerak. Ta'mirlash 1,{1}} soat ishlagandan keyin/12 oy yoki jo'natilgandan keyin 15 oy o'tgandan keyin talab qilinadi (birinchi yetib kelishi aniqlangan).
Mobil dizel generatorining mos yozuvlar rasmi




Issiq teglar: harakatlanuvchi dizel generatori, Xitoyning harakatlanuvchi dizel generatori ishlab chiqaruvchilari, zavod














